If your channel letter “cuts” are not accurate, please try the following steps to make sure that your V3 tape measure is correctly installed. (We found that one of our clients tape measure wasn’t installed properly).

 

 

1. Use the right hand side machine to “V” cut on any return off cut longer than 300mm.

 

 

 

2. After cutting the “V” move the return to the right to the 100mm position. Cut again. (So the dimension should be 100mm)

 

 

 

3. Then move your first “V” cut to the 200mm position and see where the position of last cut is.

 

If your second “V” cut looks like the above image, then your tape measure is not installed correctly. 

It must be on 100mm.

 

 

 

4. Mark the V3 table using a sharp needle or pen and re-install your tape measure so that it lines up with the table marking. As in the image below.

 

 

 

Then double check by doing the above process again, to confirm the Tape measure is now correct.

 